Attachment to the control valve Mounting parts and accessories
Travel tables
Note: The lever M is included in the scope of delivery.
Levers S, L, XL for attachment according to IEC 60534-6 (NAMUR) are available as acces
-
sories (see Table 3 on page 44).
Direct attachment to Type 3277-5 and Type 3277 Actuators
Actuator size Rated travel Adjustment range at positioner
1)
Required
lever
Assigned
pin position
[cm²] [mm] Min. Travel Max.
120 7.5 5.0 to 25.0 M 25
120/240/175/350 15 7.0 to 35.0 M 35
355/700/750 30 10.0 to 50.0 M 50
Attachment according to IEC 60534-6 (NAMUR)
SAMSON valves/Type 3271 Actuator Adjustment range at positioner
1)
Other valves/actuators
Required
lever
Assigned
pin position
Actuator size Rated travel
[cm²] [mm] min. Travel max.
60 and 120 with
Type 3510 Valve
7.5 3.6 to 18.0 S 17
120 7.5 5.0 to 25.0 M 25
120/240/175/350 15
7.0 to 35.0 M 35
700/750 7.5
355/700/750 15 and 30 10.0 to 50.0 M 50
1000/1400/2800 30 14.0 to 70.0 L 70
1000/1400/2800 60 20.0 to 100.0 L 100
1400/2800 120 40.0 to 200.0 XL 200
Attachment to rotary actuators according to VDI/VDE 3845
Rotary actuators
Required
lever
Assigned
pin position
Min. Opening angle Max.
24 to 100° M 90°
1)
The min./max. adjustment range is based on the NOM (nominal range) initialization mode